Differential Valve - High-Speed Valve 60–350 bar
- Maximum operating pressure: 350 bar
- Adjustment range (bar): 60–350
- Max. inlet flow rate (l/min): 160
- Surface treatment: Galvanized
Data sheet specifications:
Screw-in thread = R 3/4"
Pressure gauge connection = R 1/4"
Connections =
P = This is the connection that is inserted on the piston side—that is, at the bottom of the cylinder—between the valve and the cylinder, preferably using a T-fitting.
V2 = This is the port that is connected to the return line—that is, the line coming from the valve that controls the retraction of the cylinder.
C2 = is the port that is connected to the piston rod side, i.e., at the top of the cylinder.
M = is the connection to which a pressure gauge can optionally be connected to set the switching pressure.
Technical Information:
- The differential valve (fast/slow valve) is installed so that the hydraulic cylinder extends more quickly (the cylinder retracts using the regular pressure and flow rate).
- It ensures that, with a piston-to-rod ratio of 1:2, the cylinder extends to the preset pressure at twice the speed and with half the force.
- However, if the hydraulic cylinder does not have a surface area ratio of 1:2, then certain deviations must, of course, be expected.
- Using a differential valve does not allow for faster break-in.
Example:
A hydraulic cylinder, 100/60-1000, such as those used in log splitters, has a piston-to-rod ratio of 1:1.56. If the cylinder is driven at a flow rate of 56 liters per minute, it extends in approximately 9.5 seconds.
If a differential valve were used, this hydraulic cylinder would improve its extension time such that it would extend in approximately 3.5 seconds; of course, this extension time applies only if the cylinder does not need to switch under pressure. Under real-world operating conditions—depending on the setting of the switching pressure—this results in a longer or shorter extension time. As soon as the resistance increases and more force is required, the extension speed returns to normal, and full force is available. The switchover pressure—i.e., the pressure at which full force should be available—is adjustable on this valve. The switchover pressure can be set using the adjustment screw located on the differential valve; in other words, you set the pressure at which the cylinder should resume operating at full force. Furthermore, this valve features a pressure gauge connection that allows the switching pressure to be adjusted using, for example, a pressure gauge.
Note: A differential circuit that makes your log splitter run faster during the retract phase cannot be technically implemented with this valve—not even by installing two differential valves.