145.2 cm³ Axial-Piston Variable-Displacement Pump - Clockwise Rotation - with Load-Sensing Controller
- Axial-piston variable-displacement pumps with load-sensing controllers
- A3HG Series
- open-loop system
HOW IT WORKS: Load-Sensing Control:
- This energy-saving control system regulates the airflow and discharge pressure to the levels actually required by the load.
- The controller automatically regulates the flow rate so that the differential pressure across the throttle valve remains constant.
- The load pressure must be routed to the pump's "L" port via an external line.
- With this regulator, the pressure regulator can be adjusted remotely via the "PP" control port.
- The default setting for differential pressure is 15 bar.
- The differential pressure adjustment range is between 10 and 30 bar.